• N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY

N2XFGY/ NA2XFGY

N2XFGY/ NA2XFGY can be installed indoors, outdoors and underground, in pipes, open air, underwater or in environments where mechanical protection is available or where high mechanical tension is required during installation and operation, in mine electrical plants, equipment and mines, as well as horizontal and vertical mines, if technical standards are met. There is a height difference in the biogas pond.

$0.00
certificate:
TUV,CE
TUV,CE
CE
CE
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY
  • N2XFGY/ NA2XFGY

Description

Application and description

N2XFGY/ NA2XFGY can be installed indoors, outdoors and underground, in pipes, open air, underwater or in
environments where mechanical protection is available or where high mechanical tension is required during
installation and operation, in mine electrical plants, equipment and mines, as well as horizontal and vertical
mines, if technical standards are met. There is a height difference in the biogas pond.
                                                                                                                                                                              

Standards and certification

IEC 60502-1, VDE 0276-603
                                                                                                                                                                              

Cable structure

- Multi-strand copper/aluminum wire armouring

- Comply with DIN VDE 0295 cl.2, IEC 60228 cl.2

- Crosslinked polyethylene 2XI1 class, according to VDE 0276-603

- Color coding according to DIN VDE 0293(HD 308)

- Thermoplastic compound filling

- Flat wire and steel tape armoring

- PVC outer sheath DMV5, following HD 603.1
                                                                                                                                                                              

Technical characteristics

- Operating voltage: 600/1000 V

- Test voltage: 3500 V

- Minimum bending radius: 12 x Ø

- Operating temperature: -5º C ~ +70º C

- Fixed installation temperature: -30 º C to +70º C

- Flame retardant: IEC 60332.1

- Insulation resistance: >20 MΩ x km
                                                                                                                                                                              

Cable parameter

Core number x conductor Cross area # x mm²

Conductor type

Insulation thickness

Mm

Sheath thickness

Mm

Communication conductor

Cross area

mm²

Nominal outside diameter

Mm

Cable weight

kg/km

3x25

rm

25,5

720

1617

218

1149

3x35

rm

28,0

1008

2010

305

1354

3x50

sm

28,0

1440

2210

435

1309

3x70

sm

31,5

2016

2925

609

1628

3x95

sm

35,0

2736

3835

827

2023

3x120

sm

38,0

3456

4662

1044

2367

3x150

sm

42,0

4320

5586

1305

2787

3x185

sm

46,5

5328

6900

1610

3372

3x240

sm

51,5

6912

8732

2088

4057

3x25+16

rm

26,5

874

1807

263

1230

3x35+16

rm

29,0

1162

2193

351

1426

3x50+25

sm

31,0

1680

2593

507

1534

3x70+35

sm

35,5

2352

3476

711

1958

3x95+50

sm

38,5

3216

4461

972

2350

3x120+70

sm

42,0

4128

5494

1247

2766

3X150+70

sm

47,0

4992

6586

1508

3339

3X185+95

sm

51,0

6240

8095

1886

3962

3X240+120

sm

58,0

8064

10400

2436

4964

4x6

rm

18,0

230

753

70

603

4x10

rm

20,0

384

1006

116

755

4x16

rm

23,5

614

1374

186

910

4x25

rm

28,0

960

1946

290

1319

4x35

rm

30,5

1344

2447

406

1572

4x50

sm

31,0

1920

2780

580

1574

4x70

sm

35,0

2688

3729

812

1992

4x95

sm

38,5

3648

4870

1102

2440

4x120

sm

41,5

4608

5949

1392

2873

4x150

sm

47,0

5760

7264

1740

3513

4x185

sm

51,0

7104

8878

2148

4147

4x240

sm

58,0

9216

11436

2784

5170

5x6

rm

19,5

288

837

88

686

5x10

rm

21,5

480

1170

145

857

5x16

rm

25,5

768

1628

233

1057

5x25

rm

30,0

1200

2325

363

1570